The Leading ODM & OEM Manufacturer
of ESD Anti-static Vinyl Flooring
Tiles and Sheets In China

What is ESD Flooring ?

ESD Flooring (Electrostatic Discharge Flooring) is a specialized flooring system designed to control and safely dissipate static electricity. It provides a reliable path for static charges to flow to the ground, preventing electrostatic buildup that may damage sensitive electronic components or affect critical operations.

Unlike standard flooring, ESD flooring is engineered with conductive materials and specific electrical resistance properties to meet different application requirements, including conductive flooring and static dissipative flooring.

ESD flooring is widely used in environments where static control is essential, such as electronics manufacturing facilities, semiconductor cleanrooms, laboratories, data centers, medical facilities, and precision production areas.

With excellent durability, easy maintenance, and stable electrical performance, ESD flooring provides long-term protection for sensitive equipment and creates a safer, controlled working environment.

ESD Flooring Series

Accessories


Welding Rod

Diameter: 4 mm,100 m/roll

Color: Available in colors matching ESD flooring

Consumption:

ESD Tile: Approx. 3.3 m/sqm

ESD Sheet: Approx. 0.8 m/sqm

Packaging: 20 rolls/carton G.W.: 32 kg/carton


Copper Foil

Diameter: 0.025mm x 12mm, 500m/roll/1.33kg

Characteristics: Refined copper, copper content 99%

Consumption:

ESD Tile: Approx. 2.4 m/sqm

ESD Sheet: Approx. 2 m/sqm

Packaging: 10 rolls/5000m/ctn G.W.: 14.5 kg/carton


Conductive Adhesive

Diameter: 20 kg/barrel

Characteristics: Good viscosity, environmental protection, containing conductive carbon fiber

Consumption:

ESD Tile/Sheet: 120sqm/barrel

Packaging:  G.W.: 21 kg/barrel

Shelf Life: 1 year

APPlication

Electronics Manufacturing
Auto Manufacturing
Pharmaceutical /Biotechnology
Clean Rooms /Laboratories
Computer Rooms
Aerospace

Project Showcase

Project Name: Electronics Factory

Country: Vietnam

Area: 2,500 sqm

Project Name: Huawei Production Base

Country: China

Area: 3,500 sqm

Project Name: Installation Site

Country: India

Area: 1,500 sqm

Why Choose ESD Flooring From Y.H.F

10 +

Countries

30 +

Years Experience

70 +

Companies

5million

Annual Output

100 %

Satisfaction

20 +

Production Lines

High Production Capacity

5 million sqm annually, backed by full-automated production lines for maximum efficiency.

Fast Delivery

In stock: Ships within 7 days after order.

Out of stock: Ships 20–25 days after order, depending on the order quantity.

Advanced Technology

Longest tempering lines in China, ensuring superior product stability and quality.

OEM/ ODM

The Experienced engineering team dedicates to improving quality and performance as well as providing the best flooring solutions.

Global Standards Compliance

Certified by IS09001,IS014001, and ISO45001; full SGS reports for TVOC, REACH, RoHS, and more.

Trusted by Industry Leaders

We want nothing more than to ensure you get your money’s worth. That’s why we offer a warranty on all our flooring.

FAQ

Professional ESD flooring is mandatory for environments with static-sensitive equipment or flammable materials, including semiconductor workshops, electronic assembly lines, cleanrooms, laboratories, data centers, lithium battery factories, and precision testing rooms. Ordinary anti-static floors only provide weak and unstable surface static resistance with uncontrolled resistance values. They easily lose anti-static function after wear and cannot pass official ESD certification. Therefore, ordinary anti-static floors cannot replace professional ESD flooring for formal factory inspection and industrial safety protection.

Compared with common epoxy and PVC floors, professional ESD flooring has four core advantages. First, permanent and stable ESD performance with integral conductive structure, avoiding failure caused by surface coating wear. Second, excellent wear resistance, stain resistance and dust-free performance suitable for cleanroom standards. Third, high safety with controlled resistance to eliminate static accumulation and leakage risks. Fourth, strong compatibility, available in roll, tile and integral floor types to adapt to heavy-duty equipment and high-frequency pedestrian traffic scenarios.

Under standard room temperature (25℃, 40%-60% humidity), the floor allows light walking 24 hours after installation, normal traffic and light equipment placement after 72 hours, and full heavy-duty operation after 7-day complete curing. Standard acceptance tests include surface and volume resistance testing, human body walking voltage testing, grounding continuity inspection, and flatness & appearance inspection. We can provide official test reports to support factory audits and project acceptance.

Daily maintenance is simple and standardized. Keep indoor humidity between 40%-60% to ensure stable static dissipation. Clean the floor with water or neutral detergent only; avoid strong acid, alkali solvents and hard abrasive tools that may damage the conductive structure. Regularly check resistance values and grounding copper strips quarterly to prevent grounding failure. With standard maintenance, the service life of ESD flooring can reach 8-15 years with consistent stable electrostatic performance.

The standard MOQ is 500 m² per color for stock colors and 1,000 m² per color for custom colors. Mixed-color orders and trial orders are available upon request.